In MDI mode, press the "SETTING" key until the Setting (Handy) screen is shown. Set the Parameter Write value to on (1). The machine will go into Alarm mode as you are setting the parameters. When finished setting the parameters set the Parameter Write value back to 0 and hit Reset. On the Setting page, TV Check is 0 (Off), Punch Code is 1 (ISO), and I/O Channel is either 0 or 1.
-
On 16-18 Series Controls using ISO format, only Baud rate and # of stop bits can be set. Always use Even parity, Word length 7, and 2 Stop bits.
-
All Parameters set by 8 bit numbers are read right to left, e.g. Bit 0 is the rightmost bit and Bit 7 is the leftmost bit.
-
To do Direct DNC, go to tape mode, set up DNC to Send and Wait for XON, hit Cycle Start at the CNC. To pause Direct DNC turn Feedrate Override to 0%.
Control Parameters
#0020=0 (I/O = 0 or =1) #0102=0 (RS-232C using DC1-DC4)
#0100 CTV=0, NCR=0, ENS=0 #0103 (Baud Rate) = 11 (9600 Baud)
#0101 SB2=1, ASI=0 (ISO), NFD=1
软件设置参数: 9600 7 2 even xon/xoff
发表于:
2008-08-07 10:48 Steven 阅读(475)