Fagor 8010
Set the following parameters on the machine
| P0 (baud rate) | 7 (9600) | | P1 (data bits) | 1 (8 data bits) | | P2 (parity) | 0 (no parity) | | P3 (stop bits) | 0 (one stop bit) | | P4 (protocol type) | 0 (general device) | | P5 (Fagor DNC is active) | No | | P6 (Debug) | No | | P7 (Abort characters) | 0 | | P8 (EOL characters) | 0 (LF) | | P9 (EOT characters) | 0 | | P10 (Xon and Xoff) | Yes | If you want you can change baud rate in the parameter P0 to: | Baud | Parameter value | | 1200 | 4 | | 2400 | 5 | | 4800 | 6 | | 9600 | 7 | | 19200 | 8 | | 38400 | 9 | | 57600 | 10 | Serial port tab | Machine name | Fagor 8010 | | Serial port | COM2 (or any free COM port) | | Baud | 9600 | | Data bits | 8 | | Parity | None | | Stop bits | 1 | Fagor 8020 | Set the following parameters on the machine | P0 (baud rate) | 7 (9600) | | P1 (data bits) | 1 (8 data bits) | | P2 (parity) | 0 (no parity) | | P3 (stop bits) | 0 (one stop bit) | | P4 (protocol type) | 0 (general device) | | P5 (Fagor DNC is active) | No | | P6 (Debug) | No | | P7 (Abort characters) | 0 | | P8 (EOL characters) | 0 (LF) | | P9 (EOT characters) | 0 | | P10 (Xon and Xoff) | Yes | If you want you can change baud rate in the parameter P0 to: | Baud | Parameter value | | 1200 | 4 | | 2400 | 5 | | 4800 | 6 | | 9600 | 7 | | 19200 | 8 | | 38400 | 9 | | 57600 | 10 | | | Set the following parameters on the PC Serial port tab | Machine name | Fagor 8020 | | Serial port | COM2 (or any free COM port) | | Baud | 9600 | | Data bits | 8 | | Parity | None | | Stop bits | 1 | |
发表于:
2008-07-25 11:15 Steven 阅读(342)
评论(0) 收藏(0)