In the 'SET' mode select manual input mode and set following parameters | INPUT DEVICE 1 | 1 | | INPUT DEVICE 2 | 1 | | INPUT UNIT | 0 | | PUNCH CODE | 1 | | TV CHECK | 0 | |
In the 'PARAM' mode set following parameters | #340 | 2 | | #341 | 2 | #310,#311,#312,#313 (baud rate) = 0000 1001 | Baud | Parameter value | | 1200 | 0000 0111 | | 2400 | 0000 1000 | | 4800 | 0000 1001 | | 9600 | 0000 1010 | Fanuc 0I-M | | Press the [Parameters] button for parameters settings | | Press the [PAGE DOWN] button and select the 'Settings 2' submode | | Set the 'MODE SELECT' switch to 'MDI' | | Set the 'NO PWE' parameter to 1 and press the 'Input' button. After changing parameters below, change this value to 0 again | | Select the 'Settings 2' submode | | Set I/O = 1 | With help of 'PAGE DOWN' and 'PAGE UP' buttons change bits in the following parameters. Please, don't change bits that didn't print in the table below #002 (stop bit and data format) | bit 0 | 0 (1 stop bit) | | bit 2 | 0 (RS232) | | bit 3 | 1 (ASCII) | | #0552 (baud rate). Set this parameter = 9 | Baud | Parameter value | | 2400 | 9 | | 4800 | 10 | | 9600 | 11 | | 19200 | 12 | | #0038 (IO device) | bit 1 | 0 | | bit 2 | 1 | | bit 4 | 0 | | bit 5 | 1 | | bit 6 | 0 | | bit 7 | 1 | | | #0051 (Parity) | #0055 (Additional parameters) | bit 0 | 1 (ASCII) | | bit 1 | 0 (CR) | | bit 2 | 0 (Protocol A) | | bit 3 | 0 (RS232) | | | Set the following parameters on the PC Serial port tab | Machine name | Fanuc 0I-M | | Serial port | COM2 (or any free COM port) | | Baud | 9600 | | Data bits | 7 | | Parity | Even | | Stop bits | 2 | |